Life sciences · Preprint
arXiv · September 25, 2026
No summary has been generated for this record yet. What follows is drawn from its source metadata only.
Preprint.
No findings were extractable from the material analysed.
Safety was not reported in the material analysed. Check the source before drawing any conclusion about harm.
The source did not state who this applies to in practice.
Graded across the dimensions that decide whether you should act, each from what the source actually supports. There is no single score, and where a dimension was not assessed it says so.
This record has not been graded across any dimension yet. Treat the label above as provisional and read the source.
What is missing. This record has no bottom line, key findings, reported figures, evidence dimensions. That is a gap in the analysis, not a judgement about the study.
Electrocardiogram (ECG) foundation models typically tokenize the signal into fixed-length patches that ignore cardiac structure, so a patch may split a heartbeat and the number of beats in each patch shifts with heart rate. This matters most for infants, whose heart rates are higher and whose ECG differs from the adult, clinic-recorded 12-lead data these models are built on. A model for infant ECG should therefore reason about heartbeats directly rather than recover them from arbitrary patches. We propose BeatGraph, which makes the heartbeat its unit of representation, modeling each 30-second window as a graph of beats. A shared beat encoder embeds each heartbeat from its waveform and inter-beat intervals, a Transformer with positional encoding orders the beats in time, and residual graph attention layers relate every beat to every other before attention pooling yields a window embedding. We pretrain BeatGraph on our new corpus of unlabeled infant recordings by predicting masked-beat embeddings, then fine-tune it for each task. One backbone supports sleep-wake detection, infant-state classification, activity-source identification (infant- or caregiver-initiated movement), and affect recognition, improving macro-F1 over the strongest baseline on each task by 0.076 to 0.158. It also transfers across age groups, reaching 0.892 AUROC on the ZZU-pECG pediatric benchmark (ages 0 to 14), within 0.001 of the best published self-supervised ECG model, and matching that model under linear evaluation on the adult PTB-XL benchmark despite infant-only pretraining. Finally, to our knowledge, we release the first public infant ECG corpus collected in homes, classrooms, and laboratory settings with state and affect labels. It contains 3,408 hours of single-channel ECG from 143 infants aged 3 to 11 months, with unlabeled pretraining data, benchmark tasks, and subject-level splits.