Life sciences · Preprint
arXiv · September 18, 2026
No summary has been generated for this record yet. What follows is drawn from its source metadata only.
Preprint.
No findings were extractable from the material analysed.
Safety was not reported in the material analysed. Check the source before drawing any conclusion about harm.
The source did not state who this applies to in practice.
Graded across the dimensions that decide whether you should act, each from what the source actually supports. There is no single score, and where a dimension was not assessed it says so.
This record has not been graded across any dimension yet. Treat the label above as provisional and read the source.
What is missing. This record has no bottom line, key findings, reported figures, evidence dimensions. That is a gap in the analysis, not a judgement about the study.
Every multiparameter persistence vectorization we know of carries a one-sided Lipschitz upper bound and nothing below it: without a lower gauge there is no sense in which the features are faithful, and no per-prediction guarantee can be built on them. This paper supplies the missing side. COMPLEX is a closed-form, training-free embedding of multiparameter modules -- slice the module along a fixed near-diagonal net, embed each slice barcode by the certified PLACE/PALACE landmark map, concatenate. Under a checkable witnessing-slice coherence condition, holding on 100% of audited pairs on Orbit5k, a single slice carries a closed-form lower gauge: separated modules stay separated in the embedding. With the standard upper bound this gives, to our knowledge, the first two-sided distortion bound for a multiparameter feature map, making faithfulness measurable. Measuring it, we find the floor tight within a small factor of realized distances yet operationally local: an RBF-SVM reaches 91% where 1-NN reaches 78% on the same features. Local per-prediction certification therefore fails for a structural reason common to every landmark embedding whose lower gauge is witnessed by one coordinate. With no learned embedding and no held-out calibration -- only a cross-validated SVM head -- COMPLEX sets the state of the art on both Orbit benchmarks (91.95% on Orbit5k, 92.98% on Orbit100k), level with or above Euler-characteristic surfaces and above transformers and graphcode. On graphs it exceeds GRIL on all four shared molecular benchmarks with one fixed configuration, including the only multiparameter method to clear COX2's majority baseline by more than three points. Closed-form selection -- of the landmark radius, the kernel (certificate-preserving), and the bifiltration set -- buys further accuracy; gradient-shaped adaptation buys none.